TECHNICAL SERVICE BULLETIN
# T09 - 02
4/01/2009
Product Service
Department
To: All RedMax Distributors and Dealers
Subject: GZ3500T Carburetor
Problem:The Air Valve could become misaligned at idle preventing advancement of the
throttle.
Solution: Install alignment bracket on the air valve. This bracket will keep the Air Valve
linkage aligned with the Throttle Valve linkage when the Throttle lever is depressed.
Additional Note: This Bulletin DOES NOT APPLY to units with Serial Number 9XXXXXXX
and up.
1. Remove the Air Box Cover, and Air Filter
2. Remove Screw from Carburetor
3. Lay Bracket into place as shown
4. Reinstall screw and tighten securely
5. Reinstall the Air Box Cover, and Air Filter
Serial Number 8XXXXXXX
GZ3500T
Important Installation Information: It is NOT necessary to
remove the Carburetor bolts or Air Horn to install this bracket.
PRODUCT MODEL SERIAL NUMBER
MTI Canada inc.
Service en français :
English services:
1 800 463-4398
1 800 463-7205
Télécopieur / Fax : 1 800 363-7157
www.mticanada.ca
Vue de la page 0
1

Résumé du contenu

Page 1 - GZ3500T

TECHNICAL SERVICE BULLETIN # T09 - 02 4/01/2009 Product Service Department To: All RedMax Distributors and Dealers Subject: GZ3500T C